Aluminized Suit Complete UK DOT/ USCG Approved IMPA 330911
DESCRIPTION:
1. General
General instructions for use,maintenance etc. are given below.
2 Scope
This Aluminized Suit Protective Clothing comply with the requirements of SOLAS 1974/2000, MSC.36(63),MSC.97(73)and,MSC.98(73)and ISO 15538: 2001.
The protective clothing offer protection for user exposure to heat. The clothing consist of garments,a hood,a pair of gaiters and a pair of gloves. If required,it should be fitted suitable breathing protective apparatus.
The protective clothing is intended to protect user against brief contact with flame and several type of heat. The property and relevant protective performance level as followed
Property(code letter) |
Performance level |
Limited flame spread(test flame to outer material) |
Pass |
Limited flame spread(test flame to lining material) |
Pass |
Heat transfer (Radiant heat) |
Level 1 |
Heat transfer (Convective heat) |
Level 1 |
Contact heat |
Level 1 |
3. Inspection
The protective clothing is to be inspected upon delivery,after each use or,if not used,annually. The Inspection shall consist of the following steps
Visual Inspection of both inside and outside.
Look for surface damage on material,seams,visor and all other components.
Look for changes in the material properties such as brittleness,stiffness,stickiness or other phenomena.
If any defect/malfunction is found,the protective clothing must be taken out of service.
4. Cleaning instructions
Wash is not recommended. Tumble-dry is not allowed (it may damage the clothing).
Dirty protective clothing may lead to a reduction in protection. Use a piece of soft rag or a smooth brush. Remove soiling by sponging down with warm water. For several soiling a mild detergent may be used.
Let the protective clothing air dry or use a fan,Maximum drying temperature 50°C.